Skip to content
Cisco Compatible

QSFP-100G-FR-S-FL Cisco QSFP-100G-FR-S Compatible 100GBase-FR1 QSFP28 1310nm 2km DOM Duplex LC SMF Optical Transceiver Module

$375.99

Free continental US shipping on orders over $99 Details

Loading...

Need a larger quantity? Request a quote

Questions? Call (888) 874-7574

Quick Specs

Form Factor
QSFP28
Rate Category
100GBase
TX Wavelength
1310nm
Interface Type
FR1
Reach
2km
Connector
Dual-LC
Cable Type
SMF
DDM
Yes
Temperature
(COM) 0°C to +70 °C
TAA
No

Overview

The FluxLight QSFP-100G-FR-S-FL is a compatible Cisco® transceiver module designed for 2km optical communication applications. The module incorporates one channel optical signal, on 1310nm center wavelength, operating at 50Gbaud data rate. The transmitter path incorporates an EML Driver and a cooled EML together. On the receiver path, the input optical signal is coupled to a Pin photodiode detector. A DSP based gearbox is used to convert 4x25Gbps NRZ signals to 1x50Gbaud PAM4 signal. Also a 4-channel retimer and FEC block are integrated in this DSP. The electrical interface is compliant with IEEE 802.3cd and QSFP28 MSA in the transmitting and receiving directions, and optical interface is compliant to IEEE 802.3cd and 100G Lambda MSA with Duplex LC connector. The module has a maximum power consumption of 3.5W.

Catalyst 93002
  • C9300X-NM-2C
  • C9300X-NM-4C
Catalyst 93502
  • C9350-NM-2C
  • C9350-NM-4C
Catalyst 94003
  • C9400-LC-12QC
  • C9400X-SUP-2
  • C9400X-SUP-2XL
Catalyst 95006
  • C9500-24Y4C
  • C9500-32C
  • C9500-32QC
  • C9500-48Y4C
  • C9500X-28C8D
  • C9500X-60L4D
Catalyst 95505
  • C9550-24L4CD
  • C9550-32C
  • C9550-48L4CD
  • C9550-64C-XL
  • C9550-96L4D
Catalyst 9600 / 96106
  • C9600-LC-24C
  • C9600-LC-40YL4CD
  • C9600X-LC-32CD
  • C9600X-LC-56YL4C
  • C9610-LC-32CD
  • C9610-LC-40YL4CD
Nexus 30007
  • N3K-C3232C
  • N3K-C3408-S
  • N3K-C3432D-S
  • N3K-C3636C-R
  • N3K-C31108TC-V
  • N3K-C34200YC-SM
  • N3K-C36180YC-R
Nexus 9100 / 9200 / 930040
  • N9K-C9316D-GX
  • N9K-C9332C
  • N9K-C9332D-GX2B
  • N9K-C9332D-H2R
  • N9K-C9336C-FX2
  • N9K-C9336C-FX2-E
  • N9K-C9348D-GX2A
  • N9K-C9348GC-FX3
  • N9K-C9348GC-FX3PH
  • N9K-C9348GC-FXP
  • N9K-C9364C
  • N9K-C9364C-GX
  • N9K-C9364C-H1
  • N9K-C9364D-GX2A
  • N9K-C92348GC-FX3
  • N9K-C92348GC-X
  • N9K-C93108TC-EX
  • N9K-C93108TC-FX
  • N9K-C93108TC-FX-24
  • N9K-C93108TC-FX3
  • N9K-C93108TC-FX3H
  • N9K-C93108TC-FX3P
  • N9K-C93180LC-EX
  • N9K-C93180YC-EX
  • N9K-C93180YC-FX
  • N9K-C93180YC-FX-24
  • N9K-C93180YC-FX3
  • N9K-C93180YC-FX3H
  • N9K-C93216TC-FX2
  • N9K-C93240YC-FX2
  • N9K-C93360YC-FX2
  • N9K-C93400LD-H1
  • N9K-C93480YLC-K1
  • N9K-C93600CD-GX
  • N9324C-SE1U
  • N9336C-SE1
  • N9348Y2C6D-SE1U
  • N9348Y12C-SE1
  • N9396T12C-SE1
  • N9396Y12C-SE1
Nexus 9500 / 980017
  • N9K-X9400-8D
  • N9K-X9400-16W
  • N9K-X9624CD-R2
  • N9K-X9624D-R2
  • N9K-X9636C-R
  • N9K-X9636C-RX
  • N9K-X9716D-GX
  • N9K-X9732C-EX
  • N9K-X9732C-FX
  • N9K-X9736C-EX
  • N9K-X9736C-FX
  • N9K-X9736C-FX3
  • N9K-X9788TC-FX
  • N9K-X9836DM-A
  • N9K-X96136YC-R
  • N9K-X97160YC-EX
  • N9K-X98900CD-A
HyperFabric2
  • HF6100-32D
  • HF6100-60L4D
Cisco 8000 Routers32
  • 8K-MPA-4D
  • 8K-MPA-16H
  • 8K-MPA-16Z2D
  • 8K-MPA-18Z1D
  • 84-MPA-2FH/6H-M
  • 84-MPA-2H12Z-M
  • 86-MPA-4FH-M
  • 86-MPA-14H2FH-M
  • 88-LC0-34H14FH
  • 88-LC0-36FH
  • 88-LC0-36FH-M
  • 88-LC1-12TH24FH-E
  • 88-LC1-36EH
  • 88-LC1-48Y8H-EM
  • 88-LC1-52Y8H-EM
  • 8011-4G24Y4H-I
  • 8011-32Y8L2H2FH
  • 8101-32FH
  • 8101-32FH-O
  • 8101-32H
  • 8102-64H
  • 8201
  • 8201-24H8FH
  • 8201-32FH
  • 8202
  • 8202-32FH-M
  • 8212-48FH-M
  • 8404-RSP1-48-EM
  • 8711-32FH-M
  • 8711-48Z-M
  • 8800-LC-36FH
  • 8800-LC-48H
8000 Secure Routers2
  • C8570-G2
  • C8650-G2
Catalyst 8000 Edge1
  • C8500-20X6C
ASR 10001
  • EPA-QSFP-1X100GE
ASR 900039
  • A9K-4HG-FLEX-FC
  • A9K-4HG-FLEX-SE
  • A9K-4HG-FLEX-TR
  • A9K-4HG-FLEX-X-FC
  • A9K-4HG-FLEX-X-SE
  • A9K-4X100GE
  • A9K-8HG-FLEX-FC
  • A9K-8HG-FLEX-SE
  • A9K-8HG-FLEX-TR
  • A9K-16X100GE-CM
  • A9K-16X100GE-FC
  • A9K-16X100GE-TR
  • A9K-20HG-FLEX-FC
  • A9K-20HG-FLEX-SE
  • A9K-20HG-FLEX-TR
  • A99-4HG-FLEX-FC
  • A99-4HG-FLEX-SE
  • A99-4HG-FLEX-TR
  • A99-4HG-FLEX-X-FC
  • A99-4HG-FLEX-X-SE
  • A99-4T-FC
  • A99-10X400GE-X-SE
  • A99-10X400GE-X-TR
  • A99-12X100GE
  • A99-12X100GE-FC
  • A99-16X100GE-X-FC
  • A99-16X100GE-X-SE
  • A99-32HG-FC
  • A99-32X100GE-CM
  • A99-32X100GE-FC
  • A99-32X100GE-TR
  • A99-32X100GE-X-SE
  • A99-32X100GE-X-TR
  • A9903-20HG-PEC
  • A9903-20HG-PEC-FC
  • ASR-9902
  • ASR-9902-FC
  • ASR-9903
  • ASR-9903-FC
NCS 520 / 540 / 56014
  • N540-24Q2C2DD-SYS
  • N540-24Q8L2DD-SYS
  • N540-24Z8Q2C-SYS
  • N540-28Z4C-SYS-A
  • N540-28Z4C-SYS-D
  • N540-ACC-SYS
  • N540-FH-AGG-SYS
  • N540-FH-CSR-SYS
  • N540X-16Z4G8Q2C-A
  • N540X-16Z4G8Q2C-D
  • N540X-16Z8Q2C-D
  • N540X-ACC-SYS
  • N560-IMA-2C
  • N560-IMA-2C-DD
NCS 1000 / 200016
  • NCS1K4 -1.2T-K9
  • NCS1K4 -1.2TL-K9
  • NCS1K4 -QXP-K9
  • NCS1K4-1.2T-K9
  • NCS1K4-1.2TL-K9
  • NCS1K4-1.2TLCW-K9
  • NCS1K4-OTN-XP
  • NCS1K4-OTN-XPL
  • NCS1K4-QXP-K9
  • NCS1K4-QXP-L-K9
  • NCS1K4-XP-CW-K9
  • NCS1K4-XPL-CW-K9
  • NCS2K-1.2T-MXP
  • NCS2K-1.2T-MXP-L
  • NCS2K-400G-XP
  • NCS2K-400GXP-L-K9
NCS 40002
  • NCS4K-4H-OPW-QC2
  • NCS4K-4H-QDD-P
NCS 550032
  • NC55-18H18F
  • NC55-24H12F-SE
  • NC55-24X100G-SE
  • NC55-32T16Q4H-A
  • NC55-36X100G-A-SE
  • NC55-36X100G-S
  • NC57-18DD-SE
  • NC57-24DD
  • NC57-36H-SE
  • NC57-36H6D-S
  • NC57-48Q2D-S
  • NC57-48Q2D-SE-S
  • NC57-MOD-S
  • NC57-MPA-2D4H-S
  • NCS-55A1-24H
  • NCS-55A1-24Q6H-S
  • NCS-55A1-24Q6H-SS
  • NCS-55A1-36H-S
  • NCS-55A1-36H-SE-S
  • NCS-55A1-48Q6H
  • NCS-57B1-5D24-SE
  • NCS-57B1-6D24H-S
  • NCS-57C1-48Q6-S
  • NCS-57C1-48Q6-SYS
  • NCS-57C1-48Q6D-S
  • NCS-57C3-MOD-S
  • NCS-57C3-MOD-SE-S
  • NCS-57D2-18DD-S
  • NCS-5501
  • NCS-5501-SE
  • NCS-5502
  • NCS-5502-SE
Firepower and Secure Firewall16
  • CSF6K-XNM-2X100G
  • CSF6K-XNM-4X200G
  • CSF6160-A-ASA-K9
  • CSF6160-A-TD-K9
  • CSF6170-A-ASA-K9
  • CSF6170-A-TD-K9
  • FPR3K-XNM-2X100G
  • FPR4K-NM-2X100G
  • FPR4K-X-NM-2X100G
  • FPR4K-X-NM-2X400G
  • FPR4K-X-NM-4X200G
  • FPR4K-XNM-2X100G
  • FPR4K-XNM-2X400G
  • FPR4K-XNM-4X200G
  • FPR9K-NM-2X100G
  • FPR9K-NM-4X100G
UCS Fabric Interconnects and Chassis16
  • UCS-FI-6454
  • UCS-FI-6454-U
  • UCS-FI-6536
  • UCS-FI-6652-U
  • UCS-FI-6664-U
  • UCS-FI-64108
  • UCS-FI-64108-U
  • UCSX-FI-6454-U
  • UCSX-FI-6536
  • UCSX-FI-6536-U
  • UCSX-FI-64108-U
  • UCSX-I-9108-100G
  • UCSX-S9108-100G
  • UCSX-S9108-100G-U
  • UCSX-S9108-100GM6
  • UCSX-S9108100GM6-U
UCS VIC Adapters11
  • UCSC-M-V5D200G
  • UCSC-M-V5D200G-D
  • UCSC-M-V5D200GV2
  • UCSC-M-V5D200GV2D
  • UCSC-P-M5D100GF
  • UCSC-P-M5S100GF
  • UCSC-P-M6CD100GF
  • UCSC-P-M6DD100GF
  • UCSC-P-N7D200GF
  • UCSC-P-V5D200G
  • UCSC-P-V5D200G-D
Server Network Adapters (Intel, Mellanox, QLogic)6
  • Mellanox (Nvidia) Bluefield-3 B3140H 1 x 400GbE QSFP112 Network Interface Card
  • Mellanox (Nvidia) Bluefield-3 B3220 2 x 200GbE QSFP112 Network Interface Card
  • Mellanox (Nvidia) ConnectX-5 100GbE QSFP28 Network Interface Card
  • Mellanox (Nvidia) ConnectX-6 100GbE QSFP56 Network Interface Card
  • Mellanox (Nvidia) ConnectX-7 2 x 200GbE QSFP112 Network Interface Card
  • Mellanox (Nvidia) ConnectX-7 400GbE QSFP112 Network Interface Card

FluxLight's Full Line of 100GBase-FR1 Optical Transceiver

Licensing

The following is a list of Finisar Corporation patents Fluxlight has licensed. This licensure recognizes and compensates Finisar for their intellectual property. The QSFP-100G-FR-S-FL like all Fluxlight optical transceivers, is covered by this license agreement. Therefore, Fluxlight customers can rest assured that all products purchased are fully licensed, and our customers are under no potential liability that may ensue from the use of unlicensed optical transceiver products.

U.S. Patent Numbers: 7,184,668 (System and method of protecting eye safety during operation of a fiber optic transceiver), 7,079,775 (Integrated memory mapped controller circuit for fiber optics transceiver), 6,957,021 (Optical transceiver with memory mapped locations), 7,058,310 (System and method for protecting eye safety during operation of a fiber optic transceiver), 6,952,531 (System and method for protecting eye safety during operation of a fiber optic transceiver), 7,162,160 (System and method for protecting eye safety during operation of a fiber optic transceiver), 7,050,720 (Integrated memory mapped controller circuit for fiber optics transceiver)

Original Equipment Manufacturer (OEM) names may be registered trademarks of the respective OEM, and the OEM has neither authorized nor sponsored the use of its trademark or trade name. All OEM names are used for cross reference/comparative purposes only.

Warranty

This part is covered by our Limited Lifetime Warranty, a 10-year serviceable lifetime, and our 30-Day Money-Back Guarantee. Read the full warranty and return terms.

Reviews

No reviews yet. If you have used this part, yours would be the first.

See all customer reviews

Ready to Build Your Network?

Get compatible transceivers and cables shipped fast, with expert support when you need it.

Contact Us